Feature 73 Ergonomics: Visual and Physical
- All computer screens should be adjustable (height and distance)
- 30% of desks should be adjustable (height)
- Alternative: desktop adjustable stands or pairs of sit and stand desks
- All seats should be adjustable (height and depth)
Feature 80 Sound Reducing Surfaces
- Part 1: Ceilings
- Open offices: minimum NRC = 0.9 for entire ceiling
- Conference and teleconference rooms: minimum NRC = 0.8 for 50% of ceiling
- Part 2: Walls:
- For all walls and partitions, need to have minimum NRC = 0.8 for the following areas:
- Open offices: 25% wall area
- Private offices, conference and teleconference rooms: 25% wall area
- Cubicles: Entire partition
- Also, minimum partition height: 4 ft. (1.2 m)
- For all walls and partitions, need to have minimum NRC = 0.8 for the following areas:
Feature 82 Individual Thermal Comfort
- Thresholds for applying feature:
- Workspaces over 2150 sq. ft (200 sq. m.), need to:
- Create a thermal gradient of at least 5 degrees F (3 degrees C)
- 50% of workspaces are free address (occupants can chose where to work)
- More than 10 workstations in the same zone
- Need to provide personal thermal comfort devices
- Workspaces over 2150 sq. ft (200 sq. m.), need to:
Feature 83 Radiant Thermal Comfort
- Part 1: Lobbies and Other Common Public Spaces
- Satisfy ASHRAE 55-2013 (Thermal Comfort standard) using a radiant (hydronic or electric) system
- Applies to all lobbies and public spaces
- Part 2: Offices and Other Regularly Occupied Spaces
- Satisfy ASHRAE 55-2013 (Thermal Comfort standard) using a radiant (hydronic or electric) system
- Applies to 50% of offices and regularly-occupied spaces